Chapter 2: Installation 11
To connect the ECMS2000 transmitter:
Before connecting the ECMS2000 transmitter to the remote workstation, ensure that the resolution
and the refresh rate of the remote workstation are supported by the ECMS2000 user station. Set the
screen resolution and refresh rate of the remote workstation. Unsupported settings will cause blank
video at the user station.
NOTE: Go to www.avocent.com for updated information on supported resolutions and refresh rates.
NOTE: The ECMS2000 transmitter requires two USB ports on the remote workstation to operate correctly. The
ECMS2000 transmitter draws electrical power from these USB ports.
1. Turn off the remote workstation.
2. The ECMS2000 transmitter has two USB connectors. Connect each of these connectors to a
corresponding USB port on the remote workstation.
3. Connect the video connector on the ECMS2000 transmitter to the appropriately labeled port on
the back of the workstation.
NOTE: A VGA-only workstation can be connected to the ECMS2000 transmitter using a VGA to DVI-I adaptor.
You must configure the ECMS2000 transmitter video settings for VGA through the serial menu.
4. Connect the ECMS2000 transmitters audio and microphone connectors to the appropriately
labeled ports on the back of the workstation.
NOTE: For CD-quality audio, you must configure the ECMS2000 transmitter and the user station using the serial
menu.
5. Connect one end of the UTP cable to the ECMS2000 transmitters RJ-45 connector and turn on
the workstation.
6. Route the other end of the UTP cable to the location you have chosen for the ECMS2000 user
station. If necessary, you can extend the UTP cable via junctions or a hub (subject to normal
Ethernet cabling practices).